document.write( "Question 1056859: A nuclear reactor generating plant supplies 15.0 MW of useful power steadily for a year. Assuming that, in addition, twice this power is wasted in heat production, determine the mass (in kilograms) converted to energy in a year at this plant.
\n" ); document.write( "
\n" ); document.write( "

Algebra.Com's Answer #671926 by Alan3354(69443)\"\" \"About 
You can put this solution on YOUR website!
A nuclear reactor generating plant supplies 15.0 MW of useful power steadily for a year. Assuming that, in addition, twice this power is wasted in heat production, determine the mass (in kilograms) converted to energy in a year at this plant.
\n" ); document.write( "-----------------
\n" ); document.write( "--> a total of 45 MW for 1 year.
\n" ); document.write( "E = 45e6*365*24*3600 watt-seconds (Joules)
\n" ); document.write( "E = 1.41912e15 joules
\n" ); document.write( "----
\n" ); document.write( "E = mc^2
\n" ); document.write( "m = 1.41912/(3e8)^2
\n" ); document.write( "m = 1.5768e-2 kg
\n" ); document.write( "m =~ 0.0158 kg
\n" ); document.write( "
\n" );